Detail RC-13 Keyence
Model
RC-13
Operation method
Addition, subtraction
Operation mode
Overcount, auto reset
Return method
Manual reset, external reset, automatic reset ( in auto reset mode)
Display power
7-segment LED ( character height: 10 mm)
The number of digits* 1
6-digit display, -99, 999 to 999, 999
Power off memory time
Approx. 10 years ( at 20° C)
Mounting method
Panel mount ( embedding) , surface mount, DIN rail mount* 2
Highest counting speed
With contacts: 30 Hz, without contacts: 5 kHz ( 1: 1 ON: OFF ratio)
Input signal
No-voltage input ( with contacts, without contacts [ count input, reset input, inhibit input] )
Control output
Relay output: 1c, 250 VAC, 3 A or less ( resistive load)
Control output
One-shot output time
0.01 s to 0.5 s ( variable)
Relay
24 ms or less ( when set to 30 Hz) , 12 ms or less ( when set to 5 kHz)
DC output
12 VDC ± 10% , 50 mA maximum
Rating
Power voltage
100 to 240 VAC ± 10% , 50/ 60 Hz
Power consumption
9.5VA or less
Current consumption.
-
Noise resistance
Square wave noise generated by a noise simulator, between the power supply terminals, 2 kV for 1 ¼ s
Withstand voltage
1, 000 VAC for 1 minute ( between all the external terminals and the case)
Insulation resistance
100 M© or more ( tested with a 500 VDC megger) between all the external terminals and the case
Environmentalresistance
Operating ambient temperature
-10 to + 50° C ( 14 to 122° F) , No condensation
Operating ambient humidity
35 to 85% RH( no condensation)
Vibration resistance
10 to 55 Hz, 1.5 mm double amplitude for 2 hours in each of the X, Y, and Z directions
Shock resistance
100 m/ s2, 3 times in each of the X, Y, and Z directions
Weight
Approx. 170 g ( main unit only)
Tampilkan Lebih Banyak